DELTA V DCS SOFTWARE DOWNLOAD SERIES
AO, 8 Channel, 4 to 20 mA DO, 8 Channel, 120/230 VAC, Isolated DO, 8 Channel, 120/230 VAC, High Side DO, 8 Channel, 24 VDC, Isolated Series 2 DO, 8 Channel, 24 VDC, High Side DO, 8 Channel, 24 VDC, High Side High Density DO, 32 Channel, 24 VDC, High Side I.S. Outputs Series 2 AO, 8 Channel, 4 to 20 mA, HART 2 AO, 8 Channel, 4 to 20 mA, HART AO, 8 Channel, 4 to 20 mA I.S. Power Multifunction, 4 Channel, DI or Pulse Input SOE (Sequence of Events), 16 Channel, Standard DI or SOE DeltaV I/O Card Types AI, 8 Channel, 4 to 20 mA, HART RTD, 8 Channel Thermocouple, 8 Channel DeltaV I/O Card Typesĭiscrete Inputs DI, 8 Channel, 24 VDC, Isolated Series 2 DI, 8 Channel, 24 VDC, Dry Contact DI, 8 Channel, 24 VDC, Dry Contact DI, 8 Channel, 120 VAC, Isolated DI, 8 Channel, 120 VAC, Dry Contact DI, 8 Channel, 230 VAC, Isolated DI, 8 Channel, 230 VAC, Dry Contact High Density DI, 32 Channel, 24 VDC, Dry Contact I.S. DeltaV I/O InterfaceĪnalog Inputs Series 2 AI, 8 Channel, 4 to 20 mA, HART AI, 8 Channel, 4 to 20 mA, HART AI, 8 Channel, 4 to 20 mA AI, 8 Channel, 1-5v I.S.
Refer to DeltaV Books Online for additional information about the DeltaV System architecture. I/O Card which snaps over the I/O Terminal Block on the I/O Interface Carrier which converts field signals to a digital format for control and communications. The I/O Interface consists of the following components as illustrated above: I/O Terminal Block which snaps onto the I/O Interface Carrier to provide screw termination's for field wiring. The I/O Subsystem includes I/O Interfaces mounted on one or more 8-wide I/O Interface Carriers and an optional power source that provides power to field devices.
DeltaV System ArchitectureĢ-Wide Power/Controller Carrier 8-Wide I/OInterface Carrier Mounting Screw DIN Rail I/O Card I/O Terminal Block DeltaV I/O Interface Refer to DeltaV Books Online for additional information about the DeltaV system architecture. Maximums: 120 - Nodes 100 - Controllers / Simplex or Redundant Pairs 60 - Workstations Note: A server may be required depending on system size.
Multiple Nodes The figure above illustrates a DeltaV Control Network with eight nodes. Multiple Nodes W o r k s t a t i o n P r i m a r y H u b S e c o n d a r y H u b S y s t e m P o w e r S u p p l y, C o n t r o l l e r, a n d I / O S u b s y s t e m L e g e n d : P r i m a r y C o n t r o l N e t w o r k S e c o n d a r y C o n t r o l N e t w o r k DeltaV System Architecture The figure above illustrates a basic DeltaV Control Network. Upon completion of this module, you will be able to identify DeltaV System architecture types Software components System capacities Objectivesġ0BaseT Cable Maximum Length 100m (330ft) Workstation Controller Primary Hub Secondary Hub 10BaseT CableMaximum Length 100m (330ft) DeltaV System Architecture